• Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries
  • Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries
  • Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries
  • Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries

Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries

Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting, Electric Bicycle, Photovoltaic, Solar, Wind, Hybrid, Telecom
Nominal Voltage: 12V
Discharge Rate: Low Discharge Rate
Shape: Square Battery
Electrolyte: Acid
Samples:
US$ 103.5/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
VGG12-110
Installation
Fixed
Rechargeable
Chargeable
Weight
34kg
Design Service Life
12 Years
Warranty
2 Years
Certificate
MSDS, ISO9001, ISO14001, Ce, UL, IEC
Transport Package
Carton+Pallet for Deep Cycle Gel Solar Battery
Specification
ISO9001, ISO14001, CE, UL
Trademark
Sunstone Power or OEM
Origin
Yunnan, China
HS Code
85072000
Production Capacity
100000000 Piece/Pieces /Month

Product Description

Deep Cycle Front Terminal Gel Battery 12v 110ah for Telecom, solar power sotrage, UPS, Off-grid Hybrid Solar CCTV, Street Light, Photovoltaic, Power Plant, Wind Generator, Solar Panels / Pump, Emergency Lighting, Security & Alarm as Backup Power Supply

Sealed Maintenance Free Type and 12V Nominal Voltage Lead Acid Gel Battery 

SunStone Power Industry Co., Ltd. Supply our customers reliable products with high quality and competitive price, since we have our own Lead mine & smelter factory & plate factory & SLA battery assembling factory, the purity quotient of our lead is 99.998%. 

Introduction for VGG series

Sunstone Vanguard Gel (VGG) series battery is designed for 12 years life. It is especially for telecommunication application. The outstanding advantage of VGG series battery is that the width of battery is 19" and the two terminal batteries are in the front. Ii is very convenient for connecting bus bar and inspect after the batteries are installed in the rack. The alloy of VGG series is made through a very available way and also the positive grid is specially designed for long life.

Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries
 
 
Model Specification(10hr) Dimension/mm Weight/kg
VGG12-55 12V 55AH 227*106*222 17.7
VGG12-80 12V80AH 394*110*285 31.3
VGG12-100 12V100AH 394*110*285 35.4
VGG12-125 12V125AH 560*125*222 41.4
VGG12-150 12V150AH 551*110*287 47
VGG12-180 12V180AH 521*125*316 54.5


Feature in details 

1. Long life design 
2. Valve Regulated Construction (Sealed) 
3. Gas Recombination System 
4. Safety and Automatic Valve System 
5. Heavy Duty Grids 
6. Operation in any position 
7. Wide Operation Temperature Range 
8. Available in flame retardant ABS material for the battery case V0 
9. Float Service life of battery


Application:

Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries

Package:

Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries Shipment:
1. By sea,by air Shipping, other good shipping way also welcomed.
2.we will send products in 20-30 days after the bank receipt.
3.A tracking number and photos of products will send by email after arrange shipped.
Payment:
1.Pay through T/T, western union, PayPal…
2.Price term: FOB Zhuhai port, FOB Shenzhen port, CNF, CIF, CFR, Door to Door.
3.The customer is responsible for any tax or bank charges by their countries.
Orders:
1.Vast experience Drop shipping.
2.Small orders and sample orders are welcomed, if we have stocks.
3.shipping on time.
4.any problem can get in time communication by 24 hours.
Our Factory
Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries
Certificate

Front Access 12V Voltage 110ah SLA Battery, Gel Rechargeable UPS Batteries
Advantage:

1. The battery is full of power when it's out of factory, no need to use liquid charge;
2. no memory, no need to discharge battery use, suitable for circuit design;
3. by high partition, adsorption and strong;
4. there is no flowing liquid (poor liquid), does not leak acid and free Upside down,
5. comply with environmental requirements, ease of use,
6. the use of lead-calcium alloys, battery self-discharge is very low,
7. easy storage, less maintenance;
8. using ABS plastic shell and valve technology for safe use.

Notice

1. Don't near the hot source and don't under the sunshine.
2. Don't charge in the sealed container. 
3. Ambient temperature is important factor for the battery operation. When the ambient temperature is too high, Battery plate corrosion will be increased, while absorbing more moisture; When the ambient temperature is too low, the battery will not be full charged. All this will affect the battery life. Therefore we suggest the working ambient temperature is around 25 º C.
4. Battery charge and discharge current usually uses the concept C, the actual value of C is related to the capacity of the battery. For example, a 100AH battery: 1C = 100A. Charging current is around 0.1C; The charging current must not be bigger than 0.3C. Discharge current general requirements in 0.05 ~ 3C range.
5. After the battery is full converted to float charging, the float voltage is around 13.0V. If the charging voltage is too high will cause the battery overcharge, otherwise the battery will not be full charged. Charging voltage is abnormal, it may be caused by the battery configuration error, or it may be caused by controller failure. Do not choose the controller with bad quality.
6. No short circuit. It should be addition charge if you don't use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
7. Don't store in the space of acid gas.
8. You should be careful and regular check when use the battery. To avoid the battery don't work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
9. Depth of discharge of the battery life is also a important factor for lifetime of battery, the deeper the battery discharge, the fewer the number of cycles, so battery should avoided from deep discharge.
10. Don't put the battery in the fire, or it will explode.
11. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
12. Don't clean the battery by using the organic solution. (e.g. petrol)