Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (18)
  • Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
  • Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
  • Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
  • Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
  • Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
  • Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Company Profile
  • FAQ
  • Related Products
Overview

Basic Info.

Model NO.
SPT6-4~12
Nominal Voltage
6V
Discharge Rate
Low Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Fixed
Rechargeable
Chargeable
Nominal Capacity
4ah
Approx Weight
Approx0.68kg
Terminal
F1or F2
Container Material
ABS
Internal Resistance
Approx 25mΩ
Nominal Operating Temp.Range
25 ± 3°c
Cycle Use
7.2~7.4V (25°c177°f)
Standby Use
6.75~6.9V(25°c/77°f)
Max. Discharge Current
60A(5s)
Capacity Afected by Temperature
25°ºC (77°f) 100%
Self Discharge
at 25ºC
Transport Package
Carton+Pallet
Specification
49*72*103mm
Trademark
Sunstone Power
Origin
China
HS Code
8507200
Production Capacity
5, 000, 000 Piece / Month

Packaging & Delivery

Package Size
10.00cm * 10.00cm * 15.00cm
Package Gross Weight
2.000kg

Product Description

Product Description
Nominal Voltage 6V (3 cells) Operating Temp.Range Discharge: -15-50°C (5-122°F)
Nominal Capacity 4AH (20hr, 1.80V/cell, 25°C/77°F) Charge:0-40°C (32-104°F)
3.8AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -15-40°C (5-104°F)
3.4AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 3°C ( 77 ± 5°F)
2.4AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 14.4~14.8V (25°C/77°F) Temp.Coefficient -30mV/°C
Dimension Length            47 ± 2mm Initial Charging Current Less than 1.2A
Width              70± 2mm Standby Use 13.5~13.8V (25°C/77°F) Temp.Coefficient -20mV/°C
Container Height 101 ± 2mm No limit on Initial Charging Current
Total Height(with Terminal) 107± 2mm Capacity affected by
Temperature
40°C (104°F) 103%
Approx Weight Approx 0.68Kg 25°C (77°F) 100%
Terminal F1or f2 0°C (32°F) 86%
Container Material ABS Self Discharge SPT series batteries may be stored for up to 6 months
Max. Discharge Current 60A (5S) At 25°C (77°F) and then a freshening charge is required.
Internal Resistance Approx 25mΩ For higher temperatures the time interval will be shorter.
 
Nominal Voltage 6V (6 cells) Operating Temp.Range Discharge: -15-50°C (5-122°F)
Nominal Capacity 12AH (20hr, 1.80V/cell, 25°C/77°F) Charge:0-40°C (32-104°F)
11.3AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -15-40°C (5-104°F)
10.2AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 3°C ( 77 ± 5°F)
7.2AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 14.4~14.8V (25°C/77°F) Temp.Coefficient -30mV/°C
Dimension Length            151± 2mm Initial Charging Current Less than 3.6A
Width              50± 2mm Standby Use 13.5~13.8V (25°C/77°F) Temp.Coefficient -20mV/°C
Container Height 94 ± 2mm No limit on Initial Charging Current
Total Height(with Terminal) 100± 2mm Capacity affected by
Temperature
40°C (104°F) 103%
Approx Weight Approx 1.8Kg 25°C (77°F) 100%
Terminal F1or f2 0°C (32°F) 86%
Container Material ABS Self Discharge SPT series batteries may be stored for up to 6 months
Max. Discharge Current 180A (5S) At 25°C (77°F) and then a freshening charge is required.
Internal Resistance Approx 10mΩ For higher temperatures the time interval will be shorter.
 
Detailed Photos
Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery
 
Company Profile

Rechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS BatteryRechargeable 6V 4ah 12ah AGM Solar Power Lead Acid UPS Battery

FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't near the hot source and don't under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid
corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the
electrolyte.
8. Don't clean the battery by using the organic solution. (e.g. petrol) 