12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting, Electric Bicycle, Photovoltaic, Solar, Wind, Hybrid, Telecom
Still deciding? Get samples of US$ 100/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • 12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery
  • 12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery
  • 12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery
  • 12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery
  • 12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery
  • 12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery
Find Similar Products

Basic Info.

Model NO.
ML12-100
Nominal Voltage
12V
Discharge Rate
High Discharge Rate
Shape
Flat Battery
Electrolyte
Acid
Installation
Fixed
Rechargeable
Chargeable
Weight
30kg
Color
Dark Gray or Black
Terminal
T3 or F5
Certificate
MSDS, UL, Ce, ISO14001, ISO9001
Transport Package
1 Piece Inton a Carton
Specification
328*172*214(220)mm
Trademark
Sunstone Power or OEM
Origin
Yunnan, China
HS Code
85072000
Production Capacity
100000000 Piece/Pieces /Month

Product Description

12V 100AH Deep Cycle & Sealed Maintenance Free Lead Acid Batteries, AGM type SLA/ VRLA Batteries


Introduction of ML series

Sunstone ML series vrla battery is designed for 10 years life. For this long life purpose, the plate are made by developed alloy which is more effectual for preventing corrosion. At the same time, we also according the percentage of alloy change the outlook and dimension of grid wire. It will give batteries more effective radius for chemical reaction. For this long life design life battery, new features include handles for easy lifting, copper terminals for higher current capacity and reduced damaged during transportation, designed to comply with EUROBAT ( draft IEC 896-2), IEEE, JIS and BS 6290 Part4, using UL certified components.

12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery
12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery

General Features

  • Nonspillable
  • Sealed and Maintenance-free Operation
  • High Quality and High Reliability
  • Exceptional Deep Discharge Recovery
  • Low Self-discharge
  • Long Service Life
  • Solid Copper Terminals
  • Tank-formed Plates
  • Computer-aided Design and Manufacturing

Typical Applications

  • Telecommunication equipment
  • Electronic instruments
  • Fire alarm
  • Security devices
  • UPS power supply
  • Emergency lighting

Application:
12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery

Package:12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM BatteryShipment:

1. By sea,by air Shipping, other good shipping way also welcomed.

2.we will send products in 20-30 days after the bank receipt.

3.A tracking number and photos of products will send by email after arrange shipped.

Payment:

1.Pay through T/T, western union, PayPal…

2.Price term: FOB Zhuhai port, FOB Shenzhen port, CNF, CIF, CFR, Door to Door.

3.The customer is responsible for any tax or bank charges by their countries.

Orders:

1.Vast experience Drop shipping.

2.Small orders and sample orders are welcomed, if we have stocks.

3.shipping on time.

4.any problem can get in time communication by 24 hours.

Our Factory

12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery

Certificate

12volt 100ah Valve Regulated Lead Acid VRLA Batteries AGM Battery

Advantage:

1. The battery is full of power when it's out of factory, no need to use liquid charge;

2. no memory, no need to discharge battery use, suitable for circuit design;

3. by high partition, adsorption and strong;

4. there is no flowing liquid (poor liquid), does not leak acid and free Upside down,

5. comply with environmental requirements, ease of use,

6. the use of lead-calcium alloys, battery self-discharge is very low,

7. easy storage, less maintenance;

8. using ABS plastic shell and valve technology for safe use.
 

Notice

1. Don't near the hot source and don't under the sunshine.
2. Don't charge in the sealed container. 
3. Ambient temperature is important factor for the battery operation. When the ambient temperature is too high, Battery plate corrosion will be increased, while absorbing more moisture; When the ambient temperature is too low, the battery will not be full charged. All this will affect the battery life. Therefore we suggest the working ambient temperature is around 25 º C.
4. Battery charge and discharge current usually uses the concept C, the actual value of C is related to the capacity of the battery. For example, a 100AH battery: 1C = 100A. Charging current is around 0.1C; The charging current must not be bigger than 0.3C. Discharge current general requirements in 0.05 ~ 3C range.
5. After the battery is full converted to float charging, the float voltage is around 13.0V. If the charging voltage is too high will cause the battery overcharge, otherwise the battery will not be full charged. Charging voltage is abnormal, it may be caused by the battery configuration error, or it may be caused by controller failure. Do not choose the controller with bad quality.
6. No short circuit. It should be addition charge if you don't use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
7. Don't store in the space of acid gas.
8. You should be careful and regular check when use the battery. To avoid the battery don't work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
9. Depth of discharge of the battery life is also a important factor for lifetime of battery, the deeper the battery discharge, the fewer the number of cycles, so battery should avoided from deep discharge.
10. Don't put the battery in the fire, or it will explode.
11. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
12. Don't clean the battery by using the organic solution. (e.g. petrol)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier