12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting, Boat
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • 12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
  • 12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
  • 12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
  • 12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
  • 12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
  • 12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
Find Similar Products
  • Overview
  • Product Description
  • Detailed Photos
  • Related Products
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
SPT12-18
Nominal Voltage
12V
Discharge Rate
Low Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Packaged
Rechargeable
Chargeable
Brand
Sunstone Power
Color
Black
Size
181*77*166mm
Weight
5.4kg
Container Material
ABS
Design Life
5 Years (at 25 Degree C)
Cell Quantity
6 Cells
Certificate
ISO9001, ISO14001, UL, CE, IEC
Internal Resistance
Approx 15mΩ
Standby Use
No Limit on Initial Charging Current
Self Discharge
for Higher Temperatures The Time Interval Will Be
Nominal Operating Temp.Range
25 ± 3ºC ( 77 ± 5ºF)
Transport Package
Carton+Pallet for Lead Acid Battery
Specification
ISO9001, ISO14001, UL, CE, IEC
Trademark
Sunstone Power
Origin
Yunnan
HS Code
85072000
Production Capacity
88888888PCS/Month

Product Description

12v18ah lead acid storage rechargeable battery for ups/solar 

Product Description
Nominal  Voltage 12V  (6 cells) Operating Temp.Range Discharge:   -15-50°C (5-122°F)
Nominal  Capacity 18AH (20hr, 1.80V/cell, 25°C/77°F) Charge:0-40°C (32-104°F)
17.0AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -15-40°C (5-104°F)
15.3AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 3°C ( 77 ± 5°F)
10.8AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 14.4~14.8V (25°C/77°F)  Temp.Coefficient -30mV/°C
Dimension Length                                 181.5 ± 2mm Initial Charging Current Less than 2.4A
Width                                  77 ± 2mm Standby Use 13.5~13.8V (25°C/77°F)  Temp.Coefficient -20mV/°C
Container Height                   167 ± 2mm No limit on Initial Charging Current  
Total Height(with Terminal)    167 ± 2mm Capacity affected by 40°C (104°F)              103%
Approx Weight Approx  5.35Kg Temperature 25°C (77°F)                100%
Terminal F3   0°C (32°F)                  86%
Container Material ABS Self Discharge SPT series batteries may be stored for up to 6 months
Max. Discharge Current 250A (5S) At 25°C (77°F) and then a freshening charge is required.
Internal Resistance Approx  15mΩ For higher temperatures the time interval will be shorter.
Feature: 
1. Maintenance-free operation
2. Compact design 
3. ABS case, Flame retardant V0 is available
4. Stable quality and high reliability 
5. 5years design life( at 25ºC)
Detailed Photos

12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar

Related Products

12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar

Company Profile

Sunstone Power Group Headquarters: Solid Power Industrial (Shenzhen) Co., Ltd. Has 20 years of experience producing and selling battery products. Established in 2003, the company has grown into an enterprise group that consists of two factories in China: A lead-acid battery production factory in Yichun City, Jiangxi P. R, and a lithium battery production factory in Dongguan City, Guangdong P. R.; Two overseas companies are also established: Sunstone Power Industrial GmbH in Germany, and PT. Solid Power Energi in Indonesia.

Sunstone Power Group supplies high-quality batteries and other energy products to worldwide customers located in more than 100 countries. Furthermore, our German and Indonesian companies have their own office/warehouse which always keeps stocks to provide fast logistics and service to local clients. Moreover, In Germany, we also supply the whole solution for home use solar systems, camper van solar systems, etc. Besides our own overseas companies, we also built exclusive distributors in Malaysia, Yemen, Iraq, Mauritania, South Africa, Russia, Venezuela Honduras, and Costa Rica.

12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
Project : 
12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
Client:

12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
Certification:

12V18ah Lead Acid Storage Rechargeable Battery for UPS/Solar
Sunstone Power's products have been ISO9001, ISO14001, CE, IEC61427, UL approved and so on. In addition, some of them have obtained VdS, RISTI ( by PT. TELKOM INDONESIA ) certificates. 

FAQ

Payment:

1. Pay through T/T, western union, PayPal…

2. Price term: FOB Zhuhai port, FOB Shenzhen port, CNF, CIF, CFR, Door to Door. 

3. The customer is responsible for any tax or bank charges by their countries. 

Packaging & Shipping:

1. By sea, by air Shipping, other good shipping ways also welcomed.

2. We will send products in 30-45 days after the bank receipt.

3. A tracking number and photos of products will send by email after arrange shipped.  

Notice:

1. Don't near the hot source and don't under the sunshine.

2. Don't charge in the sealed container.

3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid corrosion.

4. Don't store in the space of acid gas.

5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery if the capacity is not full or has been damaged, especially after one year using.

6. Don't put the battery in the fire, or it will explode.

7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.

8. Don't clean the battery by using the organic solution. (e.g. petrol) 