Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting, Electric Bicycle, Photovoltaic, Solar, Wind, Hybrid, Telecom
Still deciding? Get samples of US$ 79.6/Piece
Request Sample
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
  • Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
  • Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
  • Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
  • Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
  • Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
Find Similar Products

Basic Info.

Model NO.
UCG2-400
Nominal Voltage
2V
Discharge Rate
Low Discharge Rate
Shape
Flat Battery
Electrolyte
Acid
Installation
Fixed
Rechargeable
Chargeable
Warranty
2.5 Years
Certificate
MSDS, ISO9001, ISO14001, Ce, UL, IEC
Transport Package
Carton+Pallet for PV Solar Battery
Specification
211*176*329*365mm
Trademark
Sunstone Power or OEM
Origin
Yunnan, China
HS Code
85072000
Production Capacity
100000000 Piece/Pieces /Month

Product Description

Deep Cycle Gel Solar Battery 2v solar power sotrage, UPS, Off-grid Hybrid Solar CCTV, Street Light, Photovoltaic, Power Plant, Wind Generator, Solar Panels / Pump, Emergency Lighting, Security & Alarm as Backup Power Supply

2V voltage Sealed Maintenance Free Lead Acid VRLA / SLA Battery for Stand Alone Power System

2v Voltage and Telecom,Autou Control System,Engine Starting,etc,Emergency Light,UPS Usage 2v solar battery

SunStone Power Industry Co., Ltd. Supply our customers reliable products with high quality and competitive price, since we have our own Lead mine & smelter factory & plate factory & SLA battery assembling factory, the purity quotient of our lead is 99.998%. 

Introduction for UCG series

Sunstone UCG series battery is designed for 12 years life. We use two ways to adding the thickness of UCG series batteries: one is adding the thickness of plate; second is the new design for material in alloy. Both these two ways will do good to the plate to let up the corrosion from acid. At the same time, the high-tin design for the alloy will do help to the ability of deep cycle of UCG series? So UCG series has very good result in solar application.

Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System BatterySolar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
 

Feature in details 

1. Long life design 
2. Valve Regulated Construction (Sealed) 
3. Gas Recombination System 
4. Safety and Automatic Valve System 
5. Heavy Duty Grids 
6. Operation in any position 
7. Wide Operation Temperature Range 
8. Available in flame retardant ABS material for the battery case V0 
9. Float Service life of battery



Application:

Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery

Package:

Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery

Shipment:

1. By sea,by air Shipping, other good shipping way also welcomed.
2.we will send products in 20-30 days after the bank receipt.
3.A tracking number and photos of products will send by email after arrange shipped.

Payment:

1.Pay through T/T, western union, PayPal…
2.Price term: FOB Zhuhai port, FOB Shenzhen port, CNF, CIF, CFR, Door to Door.
3.The customer is responsible for any tax or bank charges by their countries.

Orders:

1.Vast experience Drop shipping.
2.Small orders and sample orders are welcomed, if we have stocks.
3.shipping on time.
4.any problem can get in time communication by 24 hours.

Our Factory

Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery

Certificate

Solar Dry Cell Lead Acid 2V 400ah Photovoltaic System Battery
Advantage:

1. The battery is full of power when it's out of factory, no need to use liquid charge;
2. no memory, no need to discharge battery use, suitable for circuit design;
3. by high partition, adsorption and strong;
4. there is no flowing liquid (poor liquid), does not leak acid and free Upside down,
5. comply with environmental requirements, ease of use,
6. the use of lead-calcium alloys, battery self-discharge is very low,
7. easy storage, less maintenance;
8. using ABS plastic shell and valve technology for safe use.

Notice

1. Don't near the hot source and don't under the sunshine.
2. Don't charge in the sealed container. 
3. Ambient temperature is important factor for the battery operation. When the ambient temperature is too high, Battery plate corrosion will be increased, while absorbing more moisture; When the ambient temperature is too low, the battery will not be full charged. All this will affect the battery life. Therefore we suggest the working ambient temperature is around 25 º C.
4. Battery charge and discharge current usually uses the concept C, the actual value of C is related to the capacity of the battery. For example, a 100AH battery: 1C = 100A. Charging current is around 0.1C; The charging current must not be bigger than 0.3C. Discharge current general requirements in 0.05 ~ 3C range.
5. After the battery is full converted to float charging, the float voltage is around 13.0V. If the charging voltage is too high will cause the battery overcharge, otherwise the battery will not be full charged. Charging voltage is abnormal, it may be caused by the battery configuration error, or it may be caused by controller failure. Do not choose the controller with bad quality.
6. No short circuit. It should be addition charge if you don't use, and single charge per three months, to avoid irreversible sulfating. The battery should be changed when the battery jar broken or the electrolyte omitted, to avoid acid corrosion.
7. Don't store in the space of acid gas.
8. You should be careful and regular check when use the battery. To avoid the battery don't work. You should change the battery if the capacity is not full or has been damage, especially after one year using.
9. Depth of discharge of the battery life is also a important factor for lifetime of battery, the deeper the battery discharge, the fewer the number of cycles, so battery should avoided from deep discharge.
10. Don't put the battery in the fire, or it will explode.
11. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the electrolyte.
12. Don't clean the battery by using the organic solution. (e.g. petrol)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier