• Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery
  • Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery
  • Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery
  • Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery
  • Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery
  • Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

Type: Lead-Acid Batteries
Usage: UPS, Lighting, Solar/Wind System
Nominal Voltage: 2V
Discharge Rate: Low Discharge Rate
Shape: Square Battery
Electrolyte: Acid
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • Overview
  • Product Specification
  • Features
  • Detailed Photos
  • Related Products
  • Application
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
UC2-400(2V400AH)
Installation
Packaged
Rechargeable
Chargeable
Sealed Type
Sealed
Size
211*176*330*365mm
Weight
25kg
Terminal Type
Copper/Lead
Expected Life Cycle
10 Years
Separator
AGM
Case Material
ABS
Cycle Time
More Than 1200 Times at 30% Dod
Certification
CE/IEC/ISO/Un38.3
Transport Package
Carton+Pallet
Specification
2V400AH
Trademark
sunstone
Origin
Shenzhen, China
HS Code
85072000
Production Capacity
1, 000, 000 PCS/Month.

Product Description

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

Product Specification
Nominal Voltage 2V ( 1cells) Operating Temp.Range Discharge: -15-50°C (5-122°F)
Nominal Capacity 420AH (20hr, 1.80V/cell, 25°C/77°F) Charge:0-40°C (32-104°F)
400AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -15-40°C (5-104°F)
340AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 3°C ( 77 ± 5°F)
240AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 2.30~2.40V (25°C/77°F) Temp.Coefficient -30mV/°C
Dimension Length 211± 2mm Initial Charging Current Less than 30A
Width 175± 2mm Standby Use 2.25~2.30V (25°C/77°F) Temp.Coefficient -20mV/°C
Container Height 329± 2mm No limit on Initial Charging Current
Total Height(with Terminal) 365 ± 2mm Capacity affected by
Temperature
40°C (104°F) 103%
Approx Weight Approx 25Kg 25°C (77°F) 100%
Terminal T5 or F7 0°C (32°F) 86%
Container Material ABS Self Discharge UC series batteries may be stored for up to 6 months
Max. Discharge Current 3000A (5S) At 25°C (77°F) and then a freshening charge is required.
Internal Resistance Approx 0.7mΩ For higher temperatures the time interval will be shorter.
Features
Maintenance-free operation
Compact design
ABS case, Flame Retardant V0 is available
Stable quality and high reliability
10 years design life (at 25°C)
Detailed Photos

 

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel BatterySolar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel BatterySolar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery
Related Products

 

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

SLPO48-100 (48V 100AH Lithium battery )
 
SLPO48-100 (48V 200AH Lithium battery )
Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

ML12-150(12V 150AH AGM Battery)
 
ML12-200(12V 200AH AGM Battery)
Application

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

Company Profile

Sunstone Power Co. established in 2003, Sunstone Power has 19 years experience of in manufacturing, marketing, brand name building of lead-acid batteries/battery plates.

Our factories (both plates factory & assembling factory) locate in Kunming City, Yunnan P.R. China. Since Yunnan P.R. is one of the main lead supply areas, we have good advantages of quality control, delivery control, and cost control. So far we are the only factory that gets pollution control permission from the government in Yunnan P.R.

Besides this, we set up our German company in Frankfurt since 2017 and Indonesia company in Jakarta since the end of 2018.

We have our own warehouse in both these two countries. It gives fast delivery and stock supporting to European and Southeast Asian markets.

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery
Partners :
Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

Certifications

Solar System Battery UC2-400 (2V400AH) Deep Cycle Battery Solar Panel Battery

Sunstone Power has been ISO9001 ,ISO14001 approved and soon on ,many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't be near the hot source and don't be under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid
corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the
electrolyte.
8. Don't clean the battery by using the organic solution. (e.g. petrol)

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now