Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Solar System
Nominal Voltage: 2V
Discharge Rate: Low Discharge Rate
Shape: Square Battery
Electrolyte: Acid
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • Overview
  • Product Specification
  • Features
  • Detailed Photos
  • Related Products
  • Application
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
OPG2-350
Installation
Fixed
Rechargeable
Chargeable
Nominal Capacity
350ah
Maintenance Type
Free
Sealed Type
Sealed
Weight
19.8kg
Voltage
2V
Terminal
M8
Container Material
ABS
Operating Tem.Range
Maximum : -40~55ºC
Cycle Use
Initial Charging Current Less Than 87.5A
Standby Use
No Limit on Initial Charging Current
Self Discharge
Stored for up to 6 Months
Transport Package
Carton with Pallet
Specification
145*206*471*526mm
Trademark
SUNSTONE
Origin
China
HS Code
85072000
Production Capacity
1000000

Product Description

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries

SunStone Power Industry Co., Ltd. Supply our customer's reliable products with high quality and competitive prices, since we have our Lead mine & smelter factory & plate factory & SLA battery assembling factory, the purity quotient of our lead is 99.998%.

Introduction for OPG/OpzV series

Sunstone OPG series battery is tubular plate & Gel electrolyte technology which is by DIN 40472 ( OPzV ) Standard. It can supply longer life than the OPS series and better deep cycling use life. The cells also can be mounted horizontally or vertically, depending on requirements.
Product Specification
Nominal Voltage 2V (1 cells) Operating Temp.Range Maximum: -40~55°C (-40~131°F)
Nominal Capacity 356AH (20hr, 1.80V/cell, 25°C/77°F) Recommended: -15~50°C (5~122°F)
350AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -20~40°C (-4~104°F)
311.5AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 5°C
210AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 2.35~2.40V Temp.Coefficient -5mV/°C
Dimension Length 124 ± 2mm Initial Charging Current Less Than 87.5A
Width 206 ± 2mm Standby Use 2.23V Temp.Coefficient -3mV/°C
Container Height 471 ± 2mm No limit on Initial Charging Current
Total Height(with Terminal) 506± 2mm Capacity affected by
Temperature
40°C (104°F) 103%
Approx Weight Approx 26.8Kg 25°C (77°F) 100%
Terminal M8 0°C (32°F) 86%
Container Material ABS Self Discharge OPG series batteries may be stored for up to 6 months
Max. Discharge Current 1400A (5S) At 25°C (77°F) and then a freshening charge is required
Internal Resistance Approx 0.6mΩ For higher temperatures the time interval will be shorter
Features
Tubular plates
DIN standard
ABS case, Flame Retardent V0 is available
Gel technology
Stable quality and high reliability
25 years design life (at 25°C)
Application :
Solar and Wind system
Alarm and security system
Telecommunication system
UPS
Emergency lighting
Auto control system
Electronic apparatus and equipment
DC power supply
Detailed Photos

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries
Related Products

 

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries

OPG2-1000(2V 1000AH OPzV battery )
 
OPG2-2000(2V 2000AH OPzV battery )
Application

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries

Company Profile

Sunstone Power Co. was established in 2003 in manufacturing, marketing, and brand name building of lead-acid batteries/battery plates.

Our factories (both plates factory & assembling factory) locate in Kunming City, Yunnan P.R. China. Since Yunnan P.R. is one of the main lead

supply areas, we have good advantages in quality control, delivery control, and cost control. So far we are the only factory that gets pollution

control permission from the government in Yunnan P.R.

Besides this, we set up our German company in Frankfurt in 2017 and an Indonesian company in Jakarta at the end of 2018.

We have our warehouse in both these two countries. It gives fast delivery and stock support to European and Southeast Asian markets.

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries
Partners :
Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries

Certifications

Hot 2volt 350ah Valve Regulated Lead Acid Gel Type Tubular Plate VRLA Batteries

Sunstone Power has been ISO9001 ,ISO14001 approved and soon on ,many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their country.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways are also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't be near the hot source and don't under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use it, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid
corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use a cotton cloth to clean, if the battery is broken down and leaks electrolyte. Please wash your skin when touch the
electrolyte.
8. Don't clean the battery by using an organic solvent. (e.g. petrol) 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now