Storage Solar deep cycle battery 2V 500AH(UC2-500)
SunStone Power Industry Co., Ltd. Supplies our customers with reliable products with high quality and competitive prices, since we have our own Lead mine & smelter factory & plate factory & SLA battery assembling factory, the purity quotient of our lead is 99.998%.
Feature in details
Long Life Design
Valve Regulated Construction
Gas Recombination System(Sealed)
Safety and Automatic Valve System
Heavy Duty Grids
Float Service life of battery
Operation in any position
Wide Operation Temperature Range
Available in flame retardant ABS material for the battery case V0
Detailed Product Description
Application
1. Uninterruptible Power Supplies (UPS)
2. Telecommunication system
3. Standby Power supply
4. Photovoltaic
5. Solar and wind system
6. Cellular radio
7. Fire alarm and security systems
8. Auto control system
Advantage
1. The battery is full of power when it's out of factory, no need to use liquid charge;
2. No memory, no need to discharge battery use, suitable for circuit design;
3. By high partition, adsorption and strong;
4. There is no flowing liquid (poor liquid), does not leak acid and free Upside down,
5. Comply with environmental requirements, ease of use,
6. The use of lead-calcium alloys, battery self-discharge is very low,
7. Easy storage, less maintenance;
8. Using ABS plastic shell and valve technology for safe use.
Product Specification
Nominal Voltage |
2V (6 cells) |
Operating Temp.Range |
Discharge: -15-50°C (5-122°F) |
Nominal Capacity |
525AH (20hr, 1.80V/cell, 25°C/77°F) |
Charge:0-40°C (32-104°F) |
500AH (10hr, 1.80V/cell, 25°C/77°F) |
Storage: -15-40°C (5-104°F) |
450AH (5hr, 1.75V/cell, 25°C/77°F) |
Nominal Operating Temp.Range |
25 ± 3°C ( 77 ± 5°F) |
320AH (1hr, 1.60V/cell, 25°C/77°F) |
Cycle Use |
14.4~14.8V (25°C/77°F) Temp.Coefficient -30mV/°C |
Dimension |
Length 241 ± 2mm |
Initial Charging Current Less than 150A |
Width 172± 2mm |
Standby Use |
13.5~13.8V (25°C/77°F) Temp.Coefficient -20mV/°C |
Container Height 330± 2mm |
No limit on Initial Charging Current |
Total Height(with Terminal) 365 ± 2mm |
Capacity affected by
Temperature |
40°C (104°F) 103% |
Approx Weight |
Approx 29.5Kg |
25°C (77°F) 100% |
Terminal |
M8 |
0°C (32°F) 86% |
Container Material |
ABS |
Self Discharge |
UC series batteries may be stored for up to 6 months |
Max. Discharge Current |
4000A (5S) |
At 25°C (77°F) and then a freshening charge is required. |
Internal Resistance |
Approx 0.6mΩ |
For higher temperatures the time interval will be shorter. |
Maintenance-free operation |
Compact design |
ABS case, Flame Retardant V0 is available |
Stable quality and high reliability |
10 years design life (at 25°C) |
Detailed Photos

Related Products





Company Profile
Sunstone Power Group Headquarters: Solid Power Industrial (Shenzhen) Co., Ltd. Has 20 years of experience producing and selling battery products. Established in 2003, the company has grown into an enterprise group that consists of two factories in China: A lead-acid battery production factory in Yichun City, Jiangxi P. R, and a lithium battery production factory in Dongguan City, Guangdong P. R.; Two overseas companies are also established: Sunstone Power Industrial GmbH in Germany, and PT. Solid Power Energi in Indonesia.
Sunstone Power Group supplies high-quality batteries and other energy products to worldwide customers located in more than 100 countries. Furthermore, our German and Indonesian companies have their own office/warehouse which always keeps stocks to provide fast logistics and service to local clients. Moreover, In Germany, we also supply the whole solution for home use solar systems, camper van solar systems, etc. Besides our own overseas companies, we also built exclusive distributors in Malaysia, Yemen, Iraq, Mauritania, South Africa, Russia, Venezuela Honduras, and Costa Rica.

Partners :

Certifications

Sunstone Power has been ISO9001 ,ISO14001 approved and soon on ,many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ
Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.
Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.
Notice:
Daily maintenance of battery pack
1. Check the voltage data on the BMS display and the actual battery voltage value to ensure the accuracy of the voltage collection of the BMS.
f they are inconsistent, proofreading is required. The error between the collected voltage and the actual battery voltage does not exceed 10mV.
2. Check the temperature collection data and actual temperature value of the BMS, and the data the error between the collected data and the actual temperature value is not allowed to exceed 3°C, to ensure that the battery will not be charged or discharged when the temperature is too high or too
low.
3. Check the BMS current collected data and actual current value, the error is not allowed to exceed 1%, to ensure that the battery will not be charged or discharged by overcurrent.
4. Check the reliability of the charging equipment to ensure that the charging equipment performs charging according to the voltage and current regulations by the BMS, to ensure that the battery will not be overcharged.
5. Check the connection of the battery pack is good, the contact points are in normal contact, and there is no accumulation of dust, powder, metal chips.
Caution
1. Children are not allowed to use the batteries.
2. It is forbidden to disassemble the battery.
3. Keep batteries or battery packs away from dangerous items or materials, such as corrosive chemicals, dangerous machinery and equipment, and high-temperature environments.
4. Unreasonable use of these products may cause smoke, such as external short circuits, overcharging, and high ambient temperature. If smoke occurs, please cut off the power in time, use a carbon dioxide or dry powder fire extinguisher for treatment, and bury it with sand or mud. The crowd must be evacuated in time during the entire process.
5. Unreasonable use of this series of products may cause the single battery to swell. In severe cases, it may cause the casing to rupture or crack. In these conditions, the battery should be stopped immediately. Please contact our technical department or after-sales service department for further solutions.
6. It is forbidden to short circuit the positive and negative terminal of the battery directly, and avoid any metal or other conductive objects contacting the positive and negative terminal of the battery. This operation may cause personal injury or property damage.
7. It is forbidden to immerse the battery in water or other conductive liquids. This operation may cause personal injury or property damage.
8. It is forbidden to use this product in series or parallel with other types of batteries. It is also forbidden to connect the whole system in series or parallel operation with other batteries. These operations may cause personal injury or property loss. If necessary, please contact the relevant technical department to obtain the correct technical support.
9. It is forbidden to get wet in an environment of more than 95%RH, even immerse in water.
Otherwise, it may cause internal short circuits, loss of function, or abnormal chemical reactions, and cause fire, smoke, explosion, and other accidents.
10. It is forbidden to put the battery system on fire or to be exposed to a high-temperature environment exceeding the temperature conditions specified in this specification for a long time. These environments above the safe temperature range will cause a significant decrease in the performance and life of this product, and even cause serious consequences such as combustion and explosion.
11. It is forbidden to store and use in an environment with high static electricity or high electromagnetic radiation. Otherwise, the electronic devices in this product will be damaged, which may cause potential safety hazards.
12. Connect the positive and negative terminal of the battery system strictly by the instructions, and reverse charging is prohibited.
13. When the electrolyte leaks, avoid contacting the electrolyte with skin and eyes. In case of contact, wash the area with plenty of water and seek medical assistance. It is forbidden for any person or animal to swallow any part of the battery system or the substance contained in the battery system.
14. Protect the battery system as much as possible to avoid mechanical vibration, collision, and pressure shock, otherwise, the battery system may short circuit, resulting in high temperature and fire.