Type: Lead-Acid Batteries
Usage: UPS, Lighting, Solar System
Nominal Voltage: 12V
Discharge Rate: Low Discharge Rate
Shape: Flat Battery
Electrolyte: Acid
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • Overview
  • Product Specification
  • Features
  • Detailed Photos
  • Related Products
  • Application
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
VG12-150
Installation
Fixed
Rechargeable
Chargeable
Container Material
ABS
Gross Weight
46.5kg
Certification
ISO9001, ISO14001, CE
Delivery Terms
Ship by Sea
Transport Package
Carton+Pallet for Lead Acid Battery
Specification
551*110*288mm
Trademark
Sunstone Power
Origin
Yunnan, China
HS Code
85072000
Production Capacity
100000000 Piece/Pieces/Month

Product Description

VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System

SunStone Power Industry Co., Ltd. Supply our customers with reliable products with high quality and competitive price, since we have our Lead mine & smelter factory & plate factory & SLA battery assembling factory, the purity quotient of our lead is 99.998%. 

Introduction to the VG series

Sunstone Vanguard  (VG) series battery is designed for 10 years of life. It is especially for telecommunication applications. The outstanding advantage of the VG series battery is that the width of the battery is 19" and the two terminal batteries are in the front. It is very convenient for connecting the bus bar and inspecting it after the batteries are installed in the rack. The VGG series is made in a very available way and also the positive grid is specially designed for long life. 

 
Product Specification
Nominal Voltage 12V (6 cells) Operating Temp.Range Discharge: -15-50°C (5-122°F)
Nominal Capacity 158AH (20hr, 1.80V/cell, 25°C/77°F) Charge:0-40°C (32-104°F)
150AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -15-40°C (5-104°F)
128AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 3°C ( 77 ± 5°F)
90AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 14.4~14.8V (25°C/77°F) Temp.Coefficient -30mV/°C
Dimension Length 551 ± 2mm Initial Charging Current Less than 45A
Width 109 ± 2mm Standby Use 13.5~13.8V (25°C/77°F) Temp.Coefficient -20mV/°C
Container Height 287± 2mm No limit on Initial Charging Current
Total Height(with Terminal) 287± 2mm Capacity affected by
Temperature
40°C (104°F) 103%
Approx Weight Approx 46.5Kg 25°C (77°F) 100%
Terminal T3 0°C (32°F) 86%
Container Material ABS Self Discharge VG series batteries may be stored for up to 6 months
Max. Discharge Current 1500A (5S) At 25°C (77°F) and then a freshening charge is required.
Internal Resistance Approx 4.2mΩ For higher temperatures the time interval will be shorter.
Features
Maintenance-free operation
Compact design
ABS case, Flame Retardant V0 is available
Stable quality and high reliability
10 years design life (at 25°C)
Detailed Photos
VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System
Related Products

VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS SystemVRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS SystemBattery line:
VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System

Application

VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System

Company Profile

Sunstone Power Co. was established in 2003 in manufacturing, marketing, and brand name building of lead-acid batteries/battery plates.

Our factories (both plates factory & assembling factory) locate in Kunming City, Yunnan P.R. China. Since Yunnan P.R. is one of the main lead supply

areas, we have good advantages in quality control, delivery control, and cost control. So far we are the only factory that gets pollution control

permission from the government in Yunnan P.R.

Besides this, we set up our German company in Frankfurt in 2017 and an Indonesian company in Jakarta at the end of 2018.

We have our warehouse in both these two countries. It gives fast delivery and stock support to European and Southeast Asian markets.

VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System
VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System
Partners :
VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System

Certifications

VRLA Front Terminal AGM 12V Lead-Acid Mf Battery for UPS System

Sunstone Power has been ISO9001 ,ISO14001 approved and soon on, many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't near the hot source and don't under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid
corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the
electrolyte.
8. Don't clean the battery by using the organic solution. (e.g. petrol)  

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now