• 2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
  • 2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
  • 2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
  • 2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
  • 2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
  • 2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply

2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply

Type: Lead-Acid Batteries
Usage: UPS, Electric Power, Lighting, Electric Bicycle, Photovoltaic, Solar, Wind, Hybrid, Telecom
Nominal Voltage: 2V
Discharge Rate: Low Discharge Rate
Shape: Flat Battery
Electrolyte: Acid
Samples:
US$ 132/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2013

Suppliers with verified business licenses

Guangdong, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 30 days
to see all verified strength labels (15)
  • Overview
  • Product Specification
  • Features
  • Detailed Photos
  • Related Products
  • Application
  • Company Profile
  • Certifications
  • FAQ
Overview

Basic Info.

Model NO.
OPG2-420
Installation
Fixed
Rechargeable
Chargeable
Design Life
25 Years
Warranty
3 Years
Transport Package
Carton+Pallet
Specification
ISO9001, ISO14001, CE
Trademark
Sunstone Power
Origin
Yunnan, China
HS Code
85072000
Production Capacity
100000000 Piece/Pieces /Month

Product Description


2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply

Product Specification
Nominal  Voltage 2V  (1 cells) Operating Temp.Range Maximum: -40~55°C (-40~131°F)
Nominal  Capacity 428AH (20hr, 1.80V/cell, 25°C/77°F) Recommended: -15~50°C (5~122°F)
420AH (10hr, 1.80V/cell, 25°C/77°F) Storage: -20~40°C (-4~104°F)
374AH (5hr, 1.75V/cell, 25°C/77°F) Nominal Operating Temp.Range 25 ± 5°C
252AH (1hr, 1.60V/cell, 25°C/77°F) Cycle Use 2.35~2.40V Temp.Coefficient -5mV/°C
Dimension Length                                145 ± 2mm Initial Charging Current Less Than 100A
Width                                  206 ± 2mm Standby Use 2.23V Temp.Coefficient -3mV/°C
Container Height                  471± 2mm No limit on Initial Charging Current  
Total Height(with Terminal)   506 ± 2mm Capacity affected by
Temperature
40°C (104°F)              103%
Approx Weight Approx 31.5Kg 25°C (77°F)                100%
Terminal M8 0°C (32°F)                  86%
Container Material ABS Self Discharge OPG series batteries may be stored for up to 6 months
Max. Discharge Current 2000A (5S) At 25°C (77°F) and then a freshening charge is required internal internal
Internal Resistance Approx  0.55mΩ For higher temperatures the time interval will be shorter
 
Features
Tubular plates  
DIN standard  
ABS case, Flame Retardent V0 is available  
Gel technology  
Stable quality and high reliability  
25 years design life (at 25°C)  
Application :   
Solar and Wind system  
Alarm and security system  
Telecommunication system  
UPS  
Emergency lighting  
Auto control system   
Electronic apparatus and equipment  
DC power supply  
 
Detailed Photos

 

2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
Related Products

2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply

Application

2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply

Company Profile

Sunstone Power Co. was established in 2003 in manufacturing, marketing, and brand name building of lead-acid batteries/battery plates.

Our factories (both plates factory & assembling factory) locate in Kunming City, Yunnan P.R. China. Since Yunnan P.R. is one of the main lead

supply areas, we have good advantages in quality control, delivery control, and cost control. So far we are the only factory that gets pollution

control permission from the government in Yunnan P.R.

Besides this, we set up our German company in Frankfurt in 2017 and an Indonesian company in Jakarta at the end of 2018.

We have our warehouse in both these two countries. It gives fast delivery and stock support to European and Southeast Asian markets.

2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply
Partners :
2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply

Certifications

2V 420ah Deep Cycle Opzv Gel Solar Panel Battery Backup Power Supply

Sunstone Power has been ISO9001 ,ISO14001 approved and soon on ,many of our products obtained CE,IEC,VDS,RISTI(BY PT. TELKOM INDONESIA) certificates .
FAQ

Payment
1. Pay through T/T, western union, PayPal…
2. Price term: FOB Shenzhen port, CFR, CIF.
3. The customer is responsible for any tax or bank charges by their countries.

Packaging & Shipping
1. By sea, by air shipping, by car or train, other good shipping ways also welcomed.
2. We will send products in 30- 35 days after the bank receipt.
3. A tracking number and photos of products will send by email after arrange shipped.

Notice
1. Don't near the hot source and don't be under the sunshine.
2. Don't charge in the sealed container.
3. No short circuit. It should be the additional charge if you don't use, and a single charge per three months, to avoid
irreversible sulfating. The battery should be changed when the battery jar is broken or the electrolyte omitted, to avoid acid
corrosion.
4. Don't store in the space of acid gas.
5. You should be careful and regular check when using the battery. To avoid the battery don't work. You should change the battery
if the capacity is not full or has been damaged, especially after one year using.
6. Don't put the battery in the fire, or it will explode.
7. Please use cotton cloth to clean, if the battery is broken down and leak electrolyte. Please wash your skin when touch the
electrolyte.
8. Don't clean the battery by using the organic solution. (e.g. petrol)